+30 694 742 9747     info@viopol.com

V-Pur TP 75-000

Three-component polyurethane rigid foam system, cyclopentane blown, for the production of district heating pipe insulation according to EN 253.

  • Pipe insulation
  • Excellent thermal insulating properties
  • High mechanical resistance
  • Resistance to high temperature
  • Low Global Warming Potential (GWP)
UnitValue
Mixing ratioParts by weightV-Pur TP-75-000 100 parts
Cyclopentane 10-12 parts (*)
V-Iso M200 130 parts
MDI Index = 125
(*) depending on required foam density
Application temperature:
(both components)
°C20 – 25
Application pressure:
(High pressure machine,
both components)
Bar120 -150
Storage (Thermal shock)After pouring the products must be stored at room temperature >20°C for 2 days
Fillingone-shot process

Specimen were produced by means of high pressure machine. Final density is achieved by proper overpacking.

Test Value Unit Method
Applied density 55 Kg/m3 DIN EN ISO 845
Compressive strength >300 kPa EN 826
Closed cell content 93 % ISO 4590
Thermal Conductivity λ (initial) 0,0210 W/mK ISOMET 2114

 

The components of V-Pur TP-75-000 are supplied in separate packaging:

Polyol :
Isocyanate:
220kg drum / 1000kg IBC
250kg drum / 1250kg IBC